Yukon Oil Furnace Owner's Manual

Browse online or download Owner's Manual for Stoves Yukon Oil Furnace. Yukon Oil Furnace Owner`s manual User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 32
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Alpha American Co., 10 Industrial Blvd., Palisade, MN 56469
www.yukon-eagle.com
YUKON
EAGLE
OWNER’S
MANUAL
• Assembly
• Installation
• Operation
• Repair Parts
Model No.
LWO-112
(Oil Fired)
LWG-112
(Gas Fired)
LWO-168
(Oil Fired)
LWG-168
(Gas Fired)
CAUTION:
Read Rules And
Instructions
Carefully For
Safe Operation
IMPORTANT:
Installation must be made in accor-
dance with state and local ordi-
nances which may differ from this
installation manual.
YUKON HUSKY/EAGLE I
YUKON POLAR/EAGLE II
OIL/GAS SOLID FUEL
FIRED CENTRAL FURNACE
FOR YOUR SAFETY:
Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
FOR YOUR SAFETY:
If you smell gas:
1. Open windows
2. Don’t touch electrical switches
3. Extinguish any open flame
4. Immediately call your gas supplier
All furnaces in this owner’s manual are UL Listed in UL file #MH 11057
Page view 0
1 2 3 4 5 6 ... 31 32

Summary of Contents

Page 1 - YUKON POLAR/EAGLE II

Alpha American Co., 10 Industrial Blvd., Palisade, MN 56469www.yukon-eagle.comYUKONEAGLEOWNER’SMANUAL• Assembly• Installation• Operation• Repair Parts

Page 2

10GAS BURNER INSTALLATIONInstall burner as follows:1. Make sure hole in side of pyrolite chamber lines upwith hole in the end of the blast tube.2. Rem

Page 6 - SECONDARY AIR INTAKE COVER

14CAUTIONDo not use any smoke pipes less than 24 gauge betweenfurnace and chimney.CONNECTING SMOKE PIPESet the smoke pipe end of the furnace as close

Page 8

16FURNACE LOCATED IN CONFINED SPACEWhen the furnace is in a utility room, install two open grilles in awall or door opening to the rest of the house.

Page 9

COMBUSTION AIRMake-up outside air to the furnace for proper fuel combustionmust be provided by openings to the outside of the building. Theopenings of

Page 10 - (GAS MODELS ONLY)

18GAS FIRING UNITGAS FIRING THE UNIT.To start burner, proceed as follows:1. Make sure the manual shut-off valve is closed andcontrol knob on gas valve

Page 11

19BTU’s EquivalentPound Per Cord Value #2Weight Air Dried Fuel OilType per Cord Wood GallonsWhite Pine 1800 17,000,000 120Aspen 1900 17,500,000 125Spr

Page 13

20WHAT SIZE COAL SHOULD I BURN?The air space between the furnace grates is 1/2 inch; therefore,coal smaller than 1/2 inch can fall through the grates

Page 14

21CHECKS AND ADJUSTMENTSIf you have installed your own furnace, we ask that you call for aninspection by a Service Technician. The peace of mind and a

Page 15

22Basically, stack temperature and percentage of CO2 are a measureof stack losses for any fuel. Therefore, many of the basic principlescan be and shou

Page 16 - FRESH AIR DUCT CAPACITIES

23MAINTENANCE INSTRUCTIONSOIL BURNERA. Lubrication:1. The two oil cups on the oil burner motor should belubricated every three months with a few drops

Page 17 - COMBUSTION AIR

24IN CASE OF CHIMNEY FIRECALL THE FIRE DEPARTMENT IMMEDIATELY!EXTINGUISH THE FIRE IN FURNACE BY SETTING THETHERMOSTAT ALL THE WAY TO THE LEFT TO CLOSE

Page 18 - HAND FIRING WOOD

25SMOKE IN THE FURNACE ROOMThis condition is usually caused because the smoke is not beingdrawn up through the chimney. Other causes could be a failed

Page 19 - BEST WOOD TO BURN

26THIS CIRCULATING FAN PERFORMANCE CURVE CHART IS FOR DETERMININGMOTOR HORSEPOWER NEEDS FOR THE LWO-168 AND LWG-168THIS CIRCULATING FAN PERFORMANCE CU

Page 20

27Repair Parts — Combustion Chamber Assembly (LEFT HAND SHOWN)EAGLE-YUKON OIL/GAS — SOLID FUEL COMBINATION FURNACEModels LWO-112 and LWG-112

Page 21 - AIR CONDITIONING

28Repair Parts — Combustion Chamber Assembly (LEFT HAND SHOWN)EAGLE-YUKON OIL/GAS — SOLID FUEL COMBINATION FURNACEModels LWO-168 and LWG-168

Page 25

31Model Number: __________________________________ Serial Number: __________________________________Installation Date: _______________________________

Page 26

32YUKONEAGLEOWNER’SMANUALModel No.LWO-112 (Oil Fired)LWG-112 (Gas Fired)LWO-168 (Oil Fired)LWG-168 (Gas Fired)CAUTION:Read Rules AndInstructionsCarefu

Page 27 - Models LWO-112 and LWG-112

4IMPORTANTPlease read all instructions carefully beforeattempting installation of this unit. Installationshould only be done by a qualified installer.

Page 29

6SECONDARY AIR SHUT OFFMODELS LWO-112 & LWG-112 ONLY1. Remove round secondary air shut off disc from plasticbag.2. Screw disc to the intake cover

Page 30

7SMOKE BAFFLESThe smoke baffles are factory installed andmust be checked to see that they have notbecome dislodged during shipping. Refer toFig. 6 for

Page 32 - Model No

9OIL BURNER INSTALLATIONNOTICE• Model LWO-112 burner has a (140,000 BTU input)1.00 G.P.H. 80 degree H nozzle installed at the factory.• Model LWO-168

Comments to this Manuals

No comments